THREE PHASE UPS : 3/1 - 3/3

       

         THREE PHASE ONLINE UPS WTIHOUT ISOLATION TRANSFORMER ( 3/1 - 3/3  OMS HF )

                            3/1 15 - 30 KVA,   3/3  20 - 80 KVA

 

         •   IGBT rectifier
         •   Real digital signal processor (DSP) controlled without isolation type transformer
         •   Input power factor correction PFC (>0,99)
         •   Low total harmonic distortion level (THD 4%)
         •   High efficiency (up to 94%)
         •   Wide input voltage range
         •   Generator compatible operation
         •   Intelligent battery management system extends the lifetime of batteries
         •   Static and manual bypass
         •   Optional galvanic isolation transformer (external)
         •   Communication with computers and network systems with SNMP availability
         •   Expandable battery blocks
         •   Low installation and operation costs
         •   Different voltage applications with refer to country mains characteristic
         •   EPO ( emergency power off)
         •   50/60 Hz frequency converter version is available according to request
         •   2 year ups and battery warranty
         •   10 year spare-part possession warranty
         •   Authorized service and customer support service


 

  THREE PHASE 3/1 AND 3/3 UPS TECHNICAL SPECIFICATIONS (WITHOUT TRANSFORMER)
  MODEL UPS HF 10 UPS HF 20 UPS HF 30 UPS HF 40 UPS HF 60 UPS HF 80
  POWER (kVA) 10 20 30 40 60 80
  POWER (kW) 8 16 24 32 48 64
  DIMENSIONS WxDxH (cm) 53x82x41 53x82x41 53x82x41 53x82x41 60x80x135 60x80x135
  WEIGHT (kg) 65 65 80 85 170 190
  OPERATING TECHNIQUE   Micro controlled high frequency IGBT technology, inverter (PWM)
  INPUT
  PHASE   3 Phase + neutral +ground
  VOLTAGE   380/400 V
  VOLTAGE RANGE   ± % 20
  FREQUENCY ( Hz )   50 / 60 Hz
  FREQUENCY RANGE   ± % 10
  INPUT CURRENT THD   ≤ % 5
  INPUT POWER FACTOR   0,99
  PROTECTION   High voltage
  OUTPUT
  OUTPUT POWER FACTOR   0.8
  PHASE   3/1 : 1 Phase + neutral +ground , 3/3 : 3 Phase + neutral +ground
  VOLTAGE   3/1 : 220/230 VAC, 3/3 : 380/400 VAC
  VOLTAGE TOLERANCE   < % 1 (Online mode)
  VOLTAGE THD   <%3 for linear loads, < %5 for non-linear loads
  CREST FAKTOR   03:01
 FREKEQUENCY   50 / 60 Hz
  FREQUENCY TOLERANCE   ± % 0.01
  OVER LOAD   % 125 load 10 minute, % 150 load 1 minute, % 200 load 1 second
  EFFICIENCY   ≥ % 90
  PROTECTIONS   Overload, electronic protection for over current, thermic fuse, high voltage, over heat, low battery, PCB charger
  LCD DISPLAY   Input / output voltage and frequency, load level, inside temperature, remaining time
  TELECOMMUNICATION   Interface-port RS 232
  STATIC BY-PASS
  PHASE   3 Phase + neutral +ground
  VOLTAGE TOLERANCE   220 / 230 VAC (F-N) ± % 10 (for operating by-pass mode)
  BATTERY
  MODEL   Lead acid, maintenance free
  BATTERY PROTECTION   Constant voltage with limited current
  BATTERY TEST   Programmable battery test (optional)
  ENVIRONMENTAL FACTORS
  STORING TEMPERATURE   - 25 °C ….. + 55 °C   (15 °C …. 40 °C recommended temperature for long battery life)
  AMBIENT TEMPERATURE   0 …... + 40 °C   (20 °C …. 25 °C recommended temperature for long battery life)
  HUMIDITY   % 0-90 (non-condensing)
  OPERATING ALTITUDE   0-2000 m
  PROTECTION CLASS   IP 20
  NOISE LEVEL   < 60 dB (1 meter)

 

 




UPS REQUEST FORM
COMPANY DATE
NAME POSITION COUNTRY
ADDRESS
PHONE FAX NO GSM
WEB E-MAIL

A) UPS TECHNICAL SPECIFICATIONS
TYPE SINGLE PHASE INPUT & OUTPUT 1/1 THREE PHASE INPUT SINGLE PHASE OUTPUT 3/1 THREE PHASE INPUT THREE PHASE OUTPUT 3/3
EI TRANSFORMER
H. FREQUENCY TRF
POWER VA cos f TIME min BAT NUMBER Ah
 

B) DEVICES' POWER VALUES THAT WILL BE CONNECTED TO THE UPS
1 VA 6 VA 11 VA
2 VA 7 VA 12 VA
3 VA 8 VA 13 VA
4 VA 9 VA 14 VA
5 VA 10 VA 15 VA

C) PROBLEMS AND QUESTIONS
 

             THREE PHASE ONLINE UPS WITH ISOLATION TRANSFORMER 

          3/3  20 - 300 KVA                             

  • On-line double conversion technology
  • Intelligent ECO mode feature (>97%  efficiency)
  • High performance microprocessor controlled
  • Automatically battery test
  • IGBT technology, high frequency PWM technique
  • Static by-pass
  • Uninterruptible maintenance By-pass switch
  • Computer & network interface,
  • 32 memories for previous alerts and 4 warning report
  • HOT stand-by feature
  • Isolated output transformer
  • RS232 connection
  • Internal port for SNMP card option
  • Indicator: 4 lines, 20 characters LCD panel
  • Designing, production and technical service under the ISO 9001 certification
  • 2 year UPS and battery warranty
  • 10 year spare-part possession warranty
  • Authorized service and customer support service

 

THREE PHASE 3/3 UPS GENERAL TECHNICAL SPECIFICATIONS ( WITH TRANSFORMER )
  MODEL POWER (kVA) POWER (kW) DIMENSIONS (cm) WEIGHT (kg)
  OM UPS T 3-3 10 10 8 40x78x107 320
  OM UPS T 3-3 15 15 12 40x78x107 340
  OM UPS T 3-3 20 20 16 40x78x107 340
  OM UPS T 3-3 30 30 24 40x78x107 340
  OM UPS T 3-3 40 40 32 52x90x130 480
  OM UPS T 3-3 60 60 48 52x90x130 480
  OM UPS T 3-3 80 80 64 52x90x130 610
  OM UPS T 3-3 100 100 80 64x98x140 740
  OM UPS T 3-3 120 120 96 77x76x168 830
  OM UPS T 3-3 160 160 128 116x107x160 1030
  OM UPS T 3-3 200 200 160 116x107x160 1060
  OM UPS T 3-3 250 250 200 165x110x194 1500
  OM UPS T 3-3 300 300 240 180x110x194 1550
  INPUT
  PHASE   3 phase + Neutral +Ground
  VOLTAGE   380V/400V/415V
 VOLTAGE TOLERANCES   % 100 load : -15%+27%
  % 64 load : -45%+27%
  % 42 load : -64%+27%
  FREQUENCY   50 / 60 Hz
  FREQUENCY RANGE   ± % 10
  INPUT CURRENT THD   ≤ % 5
  INPUT POWER FACTOR   0,99
  OUTPUT
  OUTPUT POWER FACTOR   0.8
  PHASE   3 Phase + neutral +ground
  VOLTAGE   380V/400V/415V
  VOLTAGE TOLERANCE   < % 1 (online mode)
  VOLTAGE THD   < % 3
  CREST FAKTOR   3 / 1
  FREKEQUENCY   50 / 60 Hz
  FREQUENCY TOLERANCE   ± % 0.01
  OVER LOAD   % 125 load 10 min , % 150 load 1 min
  EFFICIENCY   ≥ % 92
  PROTECTIONS   Overload, electronic protection for over current, thermic fuse, high voltage, over heat, low battery, PCB charger
  LCD DISPLAY   Input/output voltage and frequency, load level, inside temperature,remaining time
  STATIC BYPASS LINE
  PHASE   3 Phase + neutral +ground
  VOLTAGE TOLERANCE   220 / 230 VAC (Phase-neutral) ± %10 (for operating in by-pass mode)
  FREQUENCY TOLERANCE   47 …. 53 Hz (adjustable, for operating in by-pass mode)
  BATTERY
  TYPE   Maintenance free
  BATTERY PROTECTION   Discharge protection, temperature compensated battery charging
  BATTERY TEST   Standard (automatic and manual)
  TELECOMMUNICATION
  INTERFACE -PORT   RS232, RS485
  DRY CONTACT CONNECTION   No mains, low battery, by-pass, output failure
  OTHER   EPO (emergency power off button) , generator interface
  ENVIRONMENTAL FACTORS
  STORING TEMPERATURE   - 25 °C ….. + 55 °C   (15 °C …. 40 °C recommended temperature for long battery life)
  OPERATINFG TEMPERATURE   0 …... + 40 °C   (20 °C …. 25 °C recommended temperature for long battery life)
  HUMIDITY   % 0-90 non-condensing
  OPERATING ALTITUDE    0 - 2000 m
  PROTECTION CLASS   IP 20
  STANDARDS   EN 50091-1-1, EN 50091-2, EN50091-3, EN55022, EN 62040-1-1, EN 62040-2, EN 62040-3 (VFI-SS-111)
  PRODUCT CERTIFICATES   CE, TSEK, ISO 9000, ISO 14001, Soncap, Gost-R

 

Copyright © 2013 Omsan - All rights reserved.
Group of Companies: Omsan Trafo Haydar Cömert
                            Omsan Grup Enerji İnşaat Ltd. Şti.
       
Corporate
Documents
Catalogs
Contact Information
About Us
Vision & Mission
Quality Policy
Central
Ş.Teğmen Kalmaz Cad. No:8/4
Ulus / ANKARA
Telephone: +90 312 311 71 25- 311 91 09
Fax: +90 0312 309 16 77
Factory
1480.(Eski 706) Sok. NO:44
İvedik OSB / ANKARA
Telephone: +90 312 394 55 54 - 394 55 53
Fax: +90 312 394 55 52